- TRIO Smartcal Pty Ltd Scope of Accreditation:
-
- Accreditation No: 15257
(Scope Last Changed 6-OCT-08 )
This facility complies with the requirements of ISO/IEC 17025:2005
1.20 Pressure and vacuum measuring devices |
 |
| .01 Pressure and vacuum measuring devices |
Calibration of pressure gauges including test gauges to AS 1349 in the range from 200 kPA to 55 MPa with least uncertainties of measurement of -
0.05%
Calibration of industrial gauges on site to AS1349 in the range 100kPa to 35 MPa |
| .11 Pressure transducers |
Self indicating only based on 1.20.01 |
| .13 Pressure recorders |
|
| 1.33 Capacitors |
| .01 Precision Capacitors |
Two terminal capacitors from 100 Hz to 1 kHz
With least uncertainties of measurement of -
0.11% from 10 pF to 100 pF
0.06% from 101 pF to 1000 nF
0.58% from 1.01 μF to 100 μF |
| 1.35 Inductors and instrument transformers |
| .01 Inductors, self and mutual |
With least uncertainties of measurement of -
0.06% from 0.1 to 500 mH at 1 kHz |
| 1.39 Indicating and recording instruments |
| .01 DC voltmeters |
With least uncertainties of measurement of -
72 μV/V + 4 μV up to 10 mV
81 μV/V from 10 to 300 mV
60 μV/V from 300 mV to 3 V
82 μV/V from 3 to 30 V
65 μV/V from 30 to 300 V
67 μV/V from 300 to 1000 V |
| .02 AC voltmeters |
With least uncertainties of measurement of -
0.31% from 30 to 300 mV and 10 to 45 Hz
0.13% from 30 to 300 mV and 45 Hz to 10 kHz
0.92% from 30 to 300 mV and 10 kHz to 500 kHz
0.19% from 300 mV to 3 V and 10 to 45 Hz
0.04% from 300 mV to 3 V and 45 Hz to 1 kHz
0.10% from 300 mV to 3 V and 1 to 20 kHz
0.34% from 300 mV to 3 V and 20 to 50 kHz
0.70% from 300 mV to 3 V and 50 to 450 kHz
0.19% from 3 to 30 V and 10 to 45 Hz
0.11% from 3 to 30 V and 45 Hz to 10 kHz
0.34% from 3 to 30 V and 10 to 90 kHz
0.06% from 30 to 300 V and 10 to 45 Hz
0.10% from 30 to 300 V and 45 Hz to 10 kHz
0.12% from 30 to 300 V 10 to 18 kHz
0.07& from 300 to 1000 V and 10 to 45 Hz
0.25% from 300 to 1000 V and 45 Hz to 1 kHz
0.31% from 300 to 1000 V and 1 to 10 kHz |
| .03 DC ammeters |
With least uncertainties of measurement of -
0.016% + 0.05 μA up to 3.3 mA
0.013% from 3.3 to 33 mA
0.013% from 33 to 330 mA
0.040% from 330 mA to 2.2 A
0.075% from 2.2 to 11 A |
|
| .04 AC ammeters |
With least uncertainties of measurement of -
0.14% from 300 μA to 2.2 A and 57 Hz to 1 kHz
0.10% from 2.2 to 11 A and 57 Hz to 1 kHz
0.7% from 300 μA to 300 mA and from 1 to 10 kHz |
|
| .09 Ohmmeters |
With least uncertainties of measurement of -
0.02% + 0.006 Ω up to 2 Ω
0.09% from 2 to 33 Ω
0.03% from 33 O to 3.3 MΩ
0.08% from 3.3 to 11 MΩ
0.12% from 11 to 33 MΩ
0.58% from 33 to 100 MΩ |
|
| .10 LCR meters |
DC resistance, capacitance and inductance
With least uncertainties of measurement of -
Based on 1.39.09, 1.33.01 and 1.35.01 |
|
| 1.41 Frequency and time measuring instruments and standards |
| .01 Frequency meters |
With least uncertainties of measurement of -
1 in 109 at frequencies up to 2.1 GHz
|
|
| .11 Counters |
With least uncertainties of measurement of -
1 in 109 at frequencies up to 2.1 GHz |
|
| .21 Frequency standards |
With least uncertainties of measurement of -
1 in 109at frequencies up to 10 MHz |
|
| .31 Calibration of frequency |
With least uncertainties of measurement of -
1 in 109 at frequencies up to 18 GHz |
|
| 1.42 Frequency analysers and waveform measuring instruments |
| .01 Frequency characteristics |
Frequency response flatness
With internal 50 Ω
4.5% at 5 mVp-p from 100 kHz to 100 MHz
5.0% at 5 mVp-p from 100 to 300 MHz
7.2% at 5 mVp-p from 300 to 600 MHz
2.8% from 10 mVp-p to 5.5 Vp-p and 100 kHz to 100 MHz
3.2% from 10 mVp-p to 5.5 Vp-p and 100 to 300 MHz
5.0% from 10 mVp-p to 5.5 Vp-p and 300 to 600 MHz
8.2% from 5 mVp-p to 5.5 Vp-p and 600 to 1000 MHz
With external 50 Ω
5.7% at 5 mVp-p from 100 kHz to 100 MHz
6.1% at 5 mVp-p from 100 kHz to 300 MHz
7.9% at 5 mVp-p from 300 kHz to 600 MHz
4.4% from 10 mVp-p to 5.5 Vp-p and 100 kHz to 100 MHz
4.6% from 10 mVp-p to 5.5 Vp-p and 100 to 300 MHz
6.1% from 10 mVp-p to 5.5 Vp-p and 300 to 600 MHz
|
|
| .02 Input characteristics |
For DC voltage with 1 MΩ input resistance
With least uncertainties of measurement of -
0.06% + 40 μV at 5 mV
0.15% from 10 to 50 mV
0.07% from 50 mV to 0.5 V
0.06% from 0.5 to 100 V
For DC voltage with 50 Ω input resistance
With least uncertainties of measurement of -
0.29% + 40 μV at 5 mV
0.38% from 10 to 50 mV
0.30% from 50 mV to 0.5 V
0.29% from 0.5 to 5 V
For square wave with 1 MΩ input resistance
With least uncertainties of measurement of -
0.12% + 40 μV at 5 mV
0.21% from 10 to 50 mV
0.13% from 50 mV to 0.5 V
0.12% from 0.5 to 100 V
For square wave with 50 Ω input resistance
With least uncertainties of measurement of -
0.29% + 40 μV at 5 mV
0.38% from 10 to 50 mV
0.30% from 50 mV to 0.5 V
0.29% from 0.5 to 100 V
|
|
| .03 Timing characteristics |
With least uncertainties of measurement of -
85 μs/s from 50 ms to 5 s
28 μs/s from 2 ns to 20 ms |
|